SILENCER LVT 

Go back

FEATURES 


Silencer LVT acoustical underlayment is suitable for ALL glue down and floating vinyl LVT, LVP, and (solid rigid core WPC, SPC, EVP) plank flooring installations. Offers the best support, moisture protection and sound absorption for your floors.


Approved and warranted for use under planks with or without pre-attached pad.


  • Made with high-density polyurethane foam
  • Reduces floor noise by providing excellent sound absorption
  • Exceeds Air Quality and Flammability standards
  • 100% recyclable and environmentally friendly

  • Quick and easy installation
  • Eliminates minor subfloor imperfections
  • Adds thermal value and suitable for use with radiant heat flooring
  • GREENGUARD Gold Certified.


GREENGUARD Gold Certification offers stricter certification criteria, considers safety factors to account for sensitive individuals (such as children and the elderly), and ensures that a product is acceptable for use in environments such as schools and healthcare facilities. It is referenced by both The Collaborative for High Performance Schools (CHPS) and the Leadership in Energy and Environmental Design (LEED) Building Rating System.



The Silencer LVT™ maintains the beauty of your floor like nothing else.
The Silencer LVT™ underlayment can stand up to the pressure.


Print Silencer LVT Flyer



ADVANTAGES

  • Silencer LVT™ is made with high-density polyurethane foam using rapidly renewable resources (soybean polyols and vegetable oils)
  • Suitable for floating, glue down, LVT, WPC (solid core vinyl planks), and vinyl plank flooring.
  • New revolutionary moisture barrier film for the best bond strength, durability and moisture protection up to 7 lbs. of pressure. In geographic areas where concrete subfloors are subject to excessive moisture, a calcium chloride moisture test is required. Vapor emission readings in excess of 7 lbs. per 1,000 square feet in 24 hrs. will require additional protection such as concrete sealant or polyethylene sheeting.

  • Crushpruf™ technology resists indentation that enables your floors to perform to its fullest potential and last a lifetime
  • Eliminates minor subfloor imperfections such as irregular surface over an open span (up to 3/16" in a 10ft radius), small concrete cracks up to 1/8" wide)
  • Offers the industry's best limited lifetime warranty
  • Suitable for radiant heat flooring systems
  • This product exceeds ASTM test for compression strength required for some vinyl plank manufacturers



APPROVED SUBSTRATES

APPROVED SUBSTRATES
  • Dry, completely cured concrete (at least 14 days old with HVAC operating)
  • 3/4" interior plywood, OSB flooring, gypcrete (must be primed before glue down)
  • Waterproofing and crack-isolation membranes
  • Cement backer units
  • Existing vinyl, wood, and laminate floors

FLOOR PREPARATION
  • Subfloor should be clean, dry and level
  • Follow the wood manufacturer's installation instructions for any additional preparation




QUICK INSTALLATION
Underlayment cuts with a knife
  1. Install Silencer LVT™ with film UP.
  2. Floating installations, roll out underlayment next to wall. Roll out next row in same manner butting underlayment close to first row (do not overlap). Seal the seams with a moisture resistant tape. Install LVT/vinyl plank per manufacturer's instructions
  3. Residential glue down installations, same as above, then apply adhesive to the top side of the underlayment per LVT/vinyl plank manufacturer's instructions. Double glue down is optional.
    Commercial glue down installations: underlayment must first be bonded to the subfloor with adhesive, preventing any movement on the floor. Double glue down is required. 
    Double glue installations, use Silencer QuickLay spray adhesive or other pressure-sensitive trowel adhesives (based on the adhesive manufacturer's requirement) using a 1/16" trowel on the subfloor. Roll out underlayment next to wall. Roll out next row in same manner butting underlayment close to first row (do not overlap). Roll with a 75 - 100 lb. roller to smooth out any air pockets and to secure a good bond to the adhesive. then apply adhesive to the top side of the underlayment per LVT/vinyl plank manufacturer's instructions. After flooring is installed, roll with a 75 – 100 lb. to secure a good bond to the adhesive.
  4. Always install flooring according to the vinyl manufacturer's installation instructions.





PACKAGING 
PACKAGING 
Available in 3' x 33.34' (100 sq. ft.) rollsTECHNICAL DATA 
100% High-Density Polyurethane foam underlayment bonded to a moisture vapor film 
Thickness — .060"
Density — 30 LBS
Weight — 2.65 oz/sq.ft.
Thermal Resistance — R-Value .17
Compression Resistance ASTM D3676 — 41.51 psi
Compression Set ASTM D3574 — 4%
Flammability Rating — Passes Federal Flammability Standards DOC-FF-1-70
Smoke Density — Passes, 110 max
Product Emissions — Exceeds VOC emissions requirements, environmentally friendly





SOUND ABSORPTION 
Impact Insulation Class (IIC) This method is to measure the impact sound transmission performance of a floor-ceiling assembly (sound transmission through the floor)
IICFlooringSub-Floor
73vinyl plank6" concrete with ceiling assembly
53vinyl plank6" concrete with NO ceiling assembly
55vinyl plank8" concrete with NO ceiling assembly
52vinyl plankwood joist with batt insulation
55vinyl plankwood joist (type 5 assembly), glue down


Sound Transmission Class (STC) This method is to measure the air-borne sound insulating property of a partition element for effectiveness in blocking sound
STCFlooringSub-Floor
68vinyl plank6" concrete with ceiling assembly
51vinyl plank6" concrete with NO ceiling assembly
55vinyl plank8" concrete with NO ceiling assembly
57vinyl plankwood joist with batt insulation
58vinyl plankwood joist (type 5 assembly), glue down
Delta IIC The db rating difference between a floor measured with an underlayment and with no underlayment 
Δ IIC — 22 — (up to a 78% db sound reduction)LEED Credits 
MR 6 — Rapidly renewable resource
EQ 4.3 — low emitting VOC's